CPA, CPD Series Data Sheet
?
200 – 550 Watt
CompactPCI ?
AC-DC and DC-DC Converters
Options
L: Output Current Latch
All CPA/CPD models exhibit a latching shutdown, which is
activated if only one output voltage is too high; see Output
Characteristic and Protection.
If option L is fitted, this latch is as well activated, if the current
limit of one output is exceeded for approx. 0.5 s.
A: Face Plate without Logo
The Power-One logo is not printed to the front plate.
input line provides safe phase to phase connection at low
mains voltages (e.g., USA 120/208 V / 60 Hz systems).
The built-in second fuse enables safe connection to the
mains, where phase and neutral line are not defined, as e.g.,
in the case of plug and socket connection to the mains via
German Schuko-plugs; see also Safety and Installation
Instructions .
C: Protective Lacquer
All boards are covered by a protective lacquer.
G: RoHS
F: Built-in Second Fuse
Available for CPA500 models only. A 2 nd fuse in the neutral
RoHS-compliant
CPD500).
for
all
six
substances
(standard
for
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written
consent of the respective divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.